The Refinex Physical AI and AIoT architecture connects physical assets, operational data, artificial intelligence (AI), and authorized equipment actions within a coordinated system. Designed for downstream operations, the architecture provides a functional framework for identifying equipment, monitoring operating conditions, evaluating operational information, and connecting approved decisions to physical processes.

Contact Refinex ↗

A layered architecture for downstream operations

In refineries, petrochemical facilities, tank farms, terminals, and pipeline operations, effective operational intelligence depends on more than collecting sensor readings. Equipment identity, process conditions, operating context, decision authority, and execution feedback must work together. The Refinex architecture organizes these responsibilities into two connected configurations: the three-engine Refinex AIoT Engine and the four-engine Refinex Physical AI Engine.

The Refinex AIoT Engine provides the identification, sensing, and AI decision functions. It organizes information from equipment, instruments, connected devices, and operational systems so that a decision process can work with asset identity and measured operating state. The Refinex Physical AI Engine contains this AIoT configuration and adds a separate Physical AI Action Engine. This fourth engine provides the controlled path from an approved decision to an equipment interface or other bounded physical response.

The distinction matters: identification, sensing, and decision processing do not themselves move a valve, change a pump setting, or dispatch a field intervention. Physical action requires a defined target, an authorized command path, validated limits, and evidence of the resulting state.

Refinex Physical AI and AIoT Engines Architecture

Refinex Physical AI Engine
Refinex AIoT Engine
01 Identification Engine
02 Sensing Engine
03 AI Decision Engine

Physical AI Action Engine

↓

Authorized response and independent physical-state verification

The diagram shows the Refinex Physical AI Engine as the outer boundary. The Refinex AIoT Engine is nested inside it and contains three vertically arranged engines. The Physical AI Action Engine sits inside the outer boundary but outside the AIoT container, receiving the AI decision output before the workflow reaches physical results.

The three engines inside the AIoT configuration

Refinex AIoT Engine

The Refinex AIoT Engine provides the identification, sensing, and AI decision functions. It organizes information from equipment, instruments, connected devices, and operational systems so that a decision process can work with asset identity and measured operating state.

Refinex Physical AI Engine

The Refinex Physical AI Engine contains this AIoT configuration and adds a separate Physical AI Action Engine. This fourth engine provides the controlled path from an approved decision to an equipment interface or other bounded physical response.

The three engines inside the AIoT configuration

01

Identification Engine

The Identification Engine associates observations and events with the correct physical asset or operational entity. In downstream facilities, relevant entities may include pumps, compressors, motors, valves, storage tanks, pipelines, instrumentation, mobile equipment, transfer equipment, and tagged materials. Depending on the application, identity may be established through equipment registers, barcode or radio-frequency identification (RFID) tags, Bluetooth Low Energy (BLE), ultra-wideband (UWB), machine-readable labels, or vision-based observations. These are technology options, not a claim of universal device compatibility.

Identity records can associate an observation with an equipment tag, plant area, process unit, asset hierarchy, or maintenance record. The system should preserve the difference between a directly read identifier, an inferred location, and a confirmed transfer or custody event. Missed reads, duplicate events, stale timestamps, and conflicting associations need quality handling before downstream decisions rely on them.

02

Sensing Engine

The Sensing Engine captures physical and process conditions relevant to the identified asset. Depending on the equipment and process, measurements may include pressure, temperature, flow, tank level, vibration, acoustic condition, motor current, valve position, speed, or selected environmental variables. Existing process instruments, condition-monitoring devices, supervisory systems, and additional connected sensors may contribute data where interfaces and data rights permit.

Measurements need context to be useful. Each reading should be associated with its asset, unit of measure, event time, ingestion time, operating mode, and quality status. The implementation should account for calibration, sampling intervals, time alignment, missing values, drift, outliers, sensor faults, and delayed or duplicated messages. A derived condition estimate should be distinguished from a directly measured value.

03

AI Decision Engine

The AI Decision Engine evaluates identified assets and their measured operating state alongside relevant historical data, process context, and approved operating rules. Depending on the defined use case and available evidence, decision functions may include anomaly detection, condition assessment, risk prioritization, forecasting, diagnosis support, or constrained operational recommendations. A proposed function must be evaluated for the specific equipment class, operating modes, data quality, and decision it is intended to support.

Outputs may include an alert, ranked inspection task, maintenance recommendation, process adjustment proposal, or request for human review. The output should include a decision identifier, model or rule version, relevant input references, timestamp, and uncertainty or confidence information where applicable. The system should abstain or escalate when observations are stale, required inputs are missing, confidence is insufficient, or the current operating state falls outside the conditions used for evaluation.

The Physical AI Action Engine

The Physical AI Action Engine is the fourth engine in the larger Refinex Physical AI configuration. It receives a decision output and manages the transition from an approved proposal to a bounded physical response. Depending on the application, a response could involve presenting an operator instruction, creating a maintenance or inspection task, requesting a controlled setpoint change, or interfacing with an approved equipment-control pathway.

A physical command path may involve an integration gateway, programmable logic controller (PLC), distributed control system (DCS), supervisory control and data acquisition (SCADA) system, drive, actuator, or robotic interface. The applicable interface and authority model must be confirmed for the site. A work-order request or dashboard recommendation is not the same as direct equipment control.

Before dispatch, the workflow should validate the target, command parameters, permissions, operating mode, and applicable limits.
Human-mediated, human-approved, and bounded autonomous modes should be distinguished.
Independent protective functions, safety instrumented functions, and existing control-system safeguards must remain within their approved design and authority.
AI decision logic should not bypass them.

After dispatch, record the command, acknowledgment, timeout or rejection, and subsequent equipment or process state. An acknowledgment confirms that a message was received or accepted by an interface; it does not prove that the intended physical change occurred. Verification requires independent evidence, such as a subsequent sensor reading, valve-position feedback, equipment state, flow response, or other suitable observation.

System boundaries and deployment layers

A practical implementation separates field acquisition, local processing, decision services, enterprise integration, and operator interaction. The exact allocation depends on latency, connectivity, data residency, cybersecurity, availability, and maintenance requirements.

01

Field layer

Asset identifiers, tags and readers, process instruments, condition sensors, cameras where appropriate, control-system signals, and equipment interfaces.

02

Edge layer

Protocol or device adapters, timestamp normalization, local validation, buffering during network interruptions, event filtering, and time-sensitive processing where justified.

03

Server or cloud layer

Historical data services, analytics, model or rules execution, event correlation, reporting, model version control, and approved application services.

04

Operations and enterprise layer

Operator workstations, maintenance workflows, asset registers, and interfaces to relevant enterprise systems.

Potential enterprise interfaces include enterprise resource planning (ERP), manufacturing execution systems (MES), computerized maintenance management systems (CMMS), and existing process-control or supervisory environments. The presence of a named system does not establish a tested connector. Each interface requires a documented data contract, ownership agreement, security review, and integration test.

Example data contract

The following fields illustrate a traceable event and action record for a downstream equipment workflow. The schema is a design example; field names, units, enumerations, retention, and mandatory status should be agreed during requirements definition.

Field Purpose Example or rule
asset_idStable equipment referenceFictional pump identifier, such as P-204
event_timeTime the observation or event occurredUTC timestamp from the source
ingestion_timeTime the platform received the recordUTC timestamp assigned at ingestion
value and unitMeasured value and engineering unitExample: 6.2 bar; use the instrument's defined unit
quality_flagValidity and quality statusValid, stale, missing, out-of-range, or suspect
operating_modeRelevant equipment or process contextStartup, steady operation, shutdown, or site-defined mode
model_versionDecision model or ruleset referenceVersion identifier used for the assessment
decision_idTraceable decision recordUnique identifier linked to input observations
command_idTraceable command or requestUnique identifier; absent when no command is issued
observed_outcomeEvidence after the action or decisionMeasured state, independent confirmation, or unverified status

Cross-cutting controls

Security, data governance, reliability, and human authority apply across all four engines. They are architectural controls, not additional engines.

01

Identity and access: authenticate devices and users, apply role-based permissions, and separate read, approve, and execute privileges.

02

Data integrity: retain source timestamps, ingestion timestamps, units, quality flags, asset associations, and lineage through processing.

03

Auditability: link observations, decisions, approvals, commands, acknowledgments, overrides, and observed outcomes with traceable identifiers.

04

Time and sequencing: define clock synchronization, event ordering, stale-data limits, duplicate handling, and late-arriving record behavior.

05

Resilience: specify buffering, retry behavior, timeout handling, communications-loss response, recovery, and safe fallback modes.

06

Human oversight: define who may review, approve, reject, override, or stop a proposed action, and how those decisions are recorded.

07

Operational safety: preserve site-approved interlocks, independent protective systems, operating procedures, and management-of-change requirements.

Evaluation and implementation considerations

Architecture evaluation should begin with a bounded downstream workflow and a clearly defined equipment or process boundary. Identify the assets, operating modes, users, data sources, control interfaces, and existing procedures. Then assess data coverage, event quality, timing, integration effort, cybersecurity, and the authority required for each decision or action.

A pilot should compare the proposed workflow with a documented baseline. Suitable measures may include asset-event completeness, incorrect identity associations, missing or delayed measurements, false-alert rate, detection delay, review workload, rejected commands, constraint violations, response time, and the proportion of actions with independently verified outcomes. Define each measure's unit, denominator, time window, and exclusions before testing.

The architecture shown here is a functional reference for requirements and system design. It does not establish that every component, device interface, connector, algorithm, or autonomous control function is currently implemented or validated at a customer site. Hardware selection, deployment topology, supported protocols, control permissions, and safety responsibilities require project-specific technical review and site acceptance.

Discuss your equipment, process data, integration environment, and operational objectives with Refinex to define a suitable architecture and an evidence-based evaluation plan.

Contact Refinex ↗